Key Features

Latest technology 3-in-1 design

Low pressure difference

Compact design with 3-in-1 heat exchanger

Meets every capacity and power requirement

Stainless steel, brazed, plated heat exchanger

Size reduction and excellent heat transfer

Corrosion prevention

Safety test against leakages

     

What are high-pressure compressed air dryers?

They ensure 100% contact between the air and refrigerant circuits. They offer excellent cooling by combining high efficiency with advanced performance.

TECHNICAL  SPECIFICATIONS

Model Capacity* Connection Size Voltage Maximum
Working
Pressure
Maximum Ambient Temperature Maximum Inlet Temperature Dimensions (mm) Weight
m³/min cfm bar ºC ºC Length Width Height kg
HRD 50 HPN 0,83 29 G ¾” 230V/1/50 Hz 45 45 50 454 361 553 36
HRD 90 HPN 1,5 53 G ¾” 230V/1/50 Hz 45 45 50 454 361 553 38
HRD 150 HPN 2,5 88 G ¾” 230V/1/50 Hz 45 45 50 453 401 623 45
HRD 220 HPN 3,67 130 G ¾” 230V/1/50 Hz 45 45 50 453 401 623 45
HRD 300 HPN 5 177 G 1 ¼" 230V/1/50 Hz 45 45 50 505 451 761 70
HRD 400 HPN 6,67 236 G 1 ¼" 230V/1/50 Hz 45 45 50 505 451 761 72
HRD 500 HPN 8,33 294 G 1 ¼" 230V/1/50 Hz 45 45 50 505 451 812 78
HRD 575 HPN 9,58 338 G 1 ¼" 230V/1/50 Hz 45 45 50 505 451 812 80
HRD 775 HPN 12,9 456 G 1 ¼" 230V/1/50 Hz 45 45 50 675 501 984 115
HRD 910 HPN 15,2 537 G 1 ¼" 230V/1/50 Hz 45 45 50 675 501 984 120
HRD 1000 HPN 16,7 590 G 2” 230V/1/50 Hz 45 45 50 947 727 1170 218
HRD 1160 HPN 19,4 685 G 2” 230V/1/50 Hz 45 45 50 947 727 1170 220
HRD 1500 HPN 25 883 G 2” 230V/1/50 Hz 45 45 50 947 727 1170 225
HRD 1600 HPN 26,7 943 G 2” 400V/3/50Hz 45 45 50 947 797 1460 263
HRD 1800 HPN 30 1050 G 2” 400V/3/50Hz 45 45 50 947 797 1460 265
HRD 2200 HPN 36,7 1296 G 2 ½" 400V/3/50Hz 45 45 50 1162 797 1495 352
HRD 2500 HPN 41,7 1473 G 2 ½" 400V/3/50Hz 45 45 50 1162 797 1495 353
HRD 2700 HPN 45 1589 G 2 ½" 400V/3/50Hz 45 45 50 1162 797 1495 355
HRD 3000 HPN 50 1766 G 2 ½" 400V/3/50Hz 45 45 50 1162 797 1495 422
HRD 3300 HPN 55 1942 G 2 ½" 400V/3/50Hz 45 45 50 1162 797 1495 423
HRD 3600 HPN 60 2119 G 2 ½" 400V/3/50Hz 45 45 50 1162 797 1495 425

- Hertz reserves its rights to change the specifications without any prior nitice.
* Nominal flow is calculated at the following conditions: Inlet Pressure: 40 bar, Inlet Temperature: 35°C Ambient Temperature 25°C for other conditions please refer to the correction factor table.