HBP US 500 / 600 / 700 / 800 / 1000 / 1250 / 1500 / 2000 /

Hertz HBP US Blower Purge Desiccant Air Dryers provide constant -40 oF pressure dew point. These dryers are designed to supply clean and very dry compressed air for critical applications. Pre-filters and after-filters are supplied along with Hertz HBP US Blower Purge Air Dryers to keep the air stream clean and maintain the integrity of the desiccant medium. A very reliable electronic controller makes sure that the dryer operates perfectly all through the service life of the dryer.

General Information

Normal Working Conditions

• 102 psi Inlet Pressure 95 oF Inlet Temperature

• 100 % Inlet Air rel. humudity

• Nominal pressure dew point is

• 104 oF / Maximum working pressure 174 psi (g)

Principle Of Operations

A centrifugal blower and high efficiency heater elliminates the use of valuable compressed air to be used for desiccant regeneration. The completely automatic drying system uses blower to pull ambient Air and pass it through the heater. This hot Air stream flows opposite to drying flow direction. Hot Air above 392 oF regenerates the moisture inside desiccant bed and strips it completely of all moisture. The advanced control system monitors the dew point and adjusts the heating / regeneration accordingly thereby providing valuable energy savings. The heater circuit is completely insulated ensuring maximum heating efficiency.

• Dew point monitoring and control

• Computer Control 

• Display Status

• Display Alarms

• Display Pressure

• Remote Start / Stop 

• Low Pressure Alarm

• Minimum Pressure monitoring valve

• High pressure switches and alarms

• Externally heated or heatless dryer functions

  integrated to the HBP dryer

PLC Is Standard

HBP Blower Purge Dryers has a very reliable electronic controller makes sure that the dryer operates perfectly all through the servicelife of the dryer. Touch screen PLC is capable of showing the cycles as well as the valves which operate on real time. It also shows the dew point.

User friendly multi-langual PLC helps the end users understand the operation system any field issues easily.

Activated Alumina

Hertz uses a mixture of adsorption media in its heatless range of desiccant dryers to achieve consistent dewpoint. Activated Alumina, Molecular Sieve and Silica Gel are used in varying ratios depending on the application.

Models and Technical Information

ModelCapacity**Connection SizeVoltageMax, Working PressureMax,Woking,TempMax,Inlet,TempIncluded Dimensions (in,)Weight
m3/mincfmpsi0F0FFilter and TypeLengthWidthHeight(lbs)
HBP US 50014.25002” NPT460V/3Ph/60Hz200120120HGO US 500C/FC/FC/FC/F
MX+MY+MP
HBP US 600176002” NPT460V/3Ph/60Hz200120120HGO US 700C/FC/FC/FC/F
MX+MY+MP
HBP US 70019.87003” ANSI B16,5460V/3Ph/60Hz200120120HGO US 1100C/FC/FC/FC/F
MX+MY+MP
HBP US 80022.78003” ANSI B16,5460V/3Ph/60Hz200120120HGO US 1100C/FC/FC/FC/F
MX+MY+MP
HBP US 100028.310003” ANSI B16,5460V/3Ph/60Hz200120120HGO US 1100C/FC/FC/FC/F
MX+MY+MP
HBP US 125035.412503” ANSI B16,5460V/3Ph/60Hz200120120HGO US 1300C/FC/FC/FC/F
MX+MY+MP
HBPUS 150042.515003” ANSI B16,5460V/3Ph/60Hz200120120HGO US 1600C/FC/FC/FC/F
MX+MY+MP
HBP US 200056.620004” ANSI B16,5460V/3Ph/60Hz200120120HF US 1900C/FC/FC/FC/F
MX+MY+MP
HBP US 250070.825004” ANSI B16,5460V/3Ph/60Hz200120120HF US 2500C/FC/FC/FC/F
MX+MY+MP
HBP US 30008530006” ANSI B16,5460V/3Ph/60Hz200120120HF US 3800C/FC/FC/FC/F
MX+MY+MP
HBP US 4000113.340006” ANSI B16,5460V/3Ph/60Hz200120120HF US 3800C/FC/FC/FC/F
MX+MY+MP
HBP US 4500127.445006” ANSI B16,5460V/3Ph/60Hz200120120HF US 5000C/FC/FC/FC/F
MX+MY+MP
HBP US 5000141.650006” ANSI B16,5460V/3Ph/60Hz200120120HF US 5000C/FC/FC/FC/F
MX+MY+MP
HBP US 6000169.960008” ANSI B16,5460V/3Ph/60Hz200120120HF US 6000C/FC/FC/FC/F
MX+MY+MP
HBP US 7000198.270008” ANSI B16,5460V/3Ph/60Hz200120120HF US 6500C/FC/FC/FC/F
MX+MY+MP
HBP US 8000226.580008” ANSI B16,5460V/3Ph/60Hz200120120HF US 8300C/FC/FC/FC/F
MX+MY+MP
HBP US 9000254.9900010” ANSI B16,5460V/3Ph/60Hz200120120HF US 8300C/FC/FC/FC/F
MX+MY+MP
HBP US 10000283.21000010” ANSI B16,5460V/3Ph/60Hz200120120HF US 10000C/FC/FC/FC/F
MX+MY+MP